The Hitachi ZX330 excavator is renowned for its reliability and efficiency in heavy-duty construction tasks. However, even the most robust machinery can encounter issues after extensive use. In this blog post, we will delve into a real-world scenario involving a Hitachi ZX330 excavator with over 15,000 hours of operation that suddenly lost its ability to rotate. We will explore the troubleshooting steps taken, the potential causes identified, and the solutions implemented to resolve the issue.

Initial Symptom Analysis of Hitachi ZX330 excavator

The Hitachi ZX330 excavator in question exhibited a specific problem: it could not rotate to the left or right at all. However, all other functions of the excavator were operating normally. This initial observation suggested that the main working pump of the excavator was functioning correctly, and the issue was isolated to the rotation mechanism.

Systematic Troubleshooting Approach

To diagnose and resolve the issue efficiently, a systematic approach was adopted, starting from the simplest potential causes to the more complex ones. Here are the detailed steps taken:

Step 1: Checking the Pressure

The first step in our troubleshooting process was to measure the pressure in the pump during the rotation attempt. The normal pressure should be around 30 MPa. However, the measured pressure was only 8 MPa, indicating a significant pressure drop. This suggested a severe leakage in the hydraulic circuit controlling the rotation.

Step 2: Identifying Potential Causes

With the significant pressure drop established, the next step in our troubleshooting process was to identify the potential causes that could lead to the observed symptom of the excavator’s inability to rotate. Several factors could contribute to this issue, and it’s essential to systematically evaluate each one to pinpoint the root cause. Below are the potential causes we considered:

1. Low Pilot Pressure

Excavator Hitachi ZX330
Excavator Hitachi ZX330

One potential cause of the problem is low pilot pressure. The pilot pressure is crucial because it acts as a signal to open the main control valve, allowing hydraulic fluid to flow to the swing motor. If the pilot pressure is insufficient, the main control valve will not open, preventing the hydraulic fluid from reaching the motor and thereby inhibiting the rotation function. Low pilot pressure could result from various issues, such as a malfunctioning pilot pump, clogged pilot lines, or a defective pressure regulator.

2. Stuck Main Control Valve

Another potential cause is a stuck main control valve. The main control valve is responsible for directing hydraulic fluid to the swing motor. If this valve becomes stuck due to debris, contamination, or mechanical failure, it will not be able to channel the hydraulic fluid properly. This obstruction would prevent the hydraulic fluid from reaching the swing motor, thereby stopping the excavator from rotating. A stuck valve often results from poor maintenance practices or the ingress of contaminants into the hydraulic system.

3. Stuck or Broken Makeup Valve in the swing Motor

The makeup valve in the swing motor also plays a critical role in maintaining the correct pressure and fluid balance within the motor. If this valve becomes stuck or if its spring is broken, it can lead to a loss of makeup fluid pressure. The makeup valve ensures that any fluid lost due to leakage is replenished, maintaining the necessary pressure for the motor to function. A malfunctioning makeup valve could result in insufficient pressure, thereby preventing the motor from operating correctly.

4. Scratched Swash Plate in the Motor

The swash plate in the motor is another critical component that could cause issues if damaged. The swash plate is responsible for converting hydraulic energy into mechanical rotation. If the swash plate has scratches or wear marks, it can create internal leakage paths between the inlet and outlet ports of the motor. This leakage would result in a significant drop in the hydraulic pressure available to drive the motor, thereby preventing the rotation function from operating as expected. Scratches on the swash plate are often a result of prolonged use, inadequate lubrication, or the presence of abrasive particles in the hydraulic fluid.

Each of these potential causes could independently or collectively contribute to the observed issue of the excavator’s inability to rotate. Therefore, it was essential to systematically investigate each factor to determine the exact cause of the problem. By eliminating each potential cause step-by-step, we aimed to narrow down the root issue and implement a targeted solution to restore the excavator’s full functionality. This methodical approach ensures that we address not just the symptoms but also the underlying cause, leading to a more effective and lasting repair.

Step 3: Eliminating Potential Causes

To systematically identify and isolate the root cause of the pressure drop and rotation issue, we methodically eliminated each potential cause. By taking a structured approach, we ensured that all possible sources of the problem were thoroughly examined.

Pilot Pressure Check

The first step in our elimination process was to verify the pilot pressure. We decided to swap the pilot oil lines of the bucket and the rotation mechanism. This involved carefully disconnecting the pilot lines and re-routing them to each other’s respective positions. After ensuring the connections were secure and there were no leaks, we operated the rotation handle. Observing the bucket functioning normally confirmed that the pilot pressure was indeed within the normal range. This successful operation indicated that the pilot pressure was not the issue, allowing us to confidently rule out the first potential cause. With the pilot pressure confirmed to be normal, we could focus on other potential areas of concern.

Main Control Valve Check

Next, our attention turned to the main control valve for the rotation mechanism. We disassembled the valve, taking care to document each step and ensure no components were lost or damaged during the process. Each part of the valve was meticulously inspected for signs of wear, sticking, or any form of mechanical obstruction. The thorough inspection revealed no abnormal wear or signs of sticking, indicating that the main control valve was functioning correctly. This allowed us to rule out the second potential cause, confirming that the issue was not related to the multi-way valve. Having eliminated the main control valve as the source of the problem, we directed our focus towards the swing motor.

Swing Motor Check

motor ayun
motor ayun

With the first two potential causes effectively eliminated, we concentrated our efforts on the swing motor, which seemed increasingly likely to be the source of the problem.

Makeup Valve Inspection in Hitachi ZX330 Excavator

We began by inspecting the makeup valve within the swing motor. This involved carefully removing the valve and examining it for any signs of sticking or a broken spring. The inspection process was thorough, ensuring that no detail was overlooked. We found that the makeup valve was in good condition, with no evidence of sticking or a broken spring. This allowed us to rule out the third potential cause, narrowing down the possible issues further.

Motor Disassembly

With the makeup valve inspection completed and no issues found, we proceeded to disassemble the motor itself, starting with the rear end cover. As we disassembled the motor, we discovered that the bearing was damaged. This finding was significant, but we continued with the disassembly to ensure there were no additional issues. Further inspection revealed that the swash plate and slippers were also damaged. These components are critical for the motor’s operation, and their damage confirmed that the motor was indeed the source of the problem. The discovery of the damaged bearing, swash plate, and slippers provided a clear explanation for the pressure drop and rotation issues, confirming that a repair or replacement of these components would be necessary to restore the excavator’s full functionality.

By methodically eliminating each potential cause, we were able to identify the true source of the problem with confidence. This thorough approach ensures that the identified issue is addressed effectively, leading to a more reliable and lasting solution.

Detailed Analysis of the swing Motor Failure

The rotation motor on the Hitachi ZX330 excavator is a swash plate axial piston motor. The damage to the motor was severe, with the following components affected:

Bearing Failure

The bearing was found to be damaged, which is a critical issue. Bearings are fundamental components in high-load hydraulic systems. With over 15,000 hours of operation, the bearing had exceeded its expected lifespan, leading to its failure.

Swash Plate and Slippers Damage

The swash plate and slippers were also damaged. The swash plate is responsible for converting the hydraulic energy into mechanical rotation. Scratches and wear on the swash plate and slippers can lead to internal leakage, reducing the efficiency of the motor and eventually leading to a complete loss of function.

Preventive Measures and Recommendations

Perawatan Rutin

The failure of the rotation motor highlights the importance of regular maintenance. Bearings, in particular, should be replaced periodically to prevent such failures. For high-load components like hydraulic pumps and motors, regular inspections and timely replacements of worn parts are crucial.

Monitoring Operating Hours

Keeping track of the operating hours of key components can help in scheduling maintenance and replacements before failures occur. For the Hitachi ZX330 excavator, components like bearings should be inspected and possibly replaced after around 10,000 to 12,000 hours of operation.

Hydraulic Fluid Quality

Maintaining the quality of hydraulic fluid is essential. Contaminated or degraded hydraulic fluid can accelerate wear and tear on components. Regularly checking and replacing hydraulic fluid can help in prolonging the lifespan of hydraulic components.

Kesimpulan

The non-rotating issue of the Hitachi ZX330 excavator was traced back to the failure of the rotation motor, specifically due to damaged bearings and worn swash plate components. By adopting a systematic troubleshooting approach, we were able to identify and address the root cause of the problem. This case underscores the importance of regular maintenance and timely replacement of critical components to ensure the reliability and efficiency of heavy-duty machinery.

Through detailed analysis and methodical troubleshooting, we can keep machinery like the Hitachi ZX330 excavator running smoothly, minimizing downtime and maximizing productivity. If you have faced similar issues or have additional insights, feel free to share your experiences in the comments below.